LIEBERT GXT3-6000RT208-KIT UPS 6000va GXT3 208v True Online 4U Rack Mount

LIEBERT GXT3-6000RT208-KIT UPS 6000va GXT3 208v True Online 4U Rack Mount

Documents [open in new window]


Specifications

Model Rating 4200W/5200VA at 127/220 (120 or 240 degrees only)
4200W/5200VA at 120/208 (120 or 240 degrees)
4200W/6000VA at 120/240 (180 degrees)
4200W/6000VA at 115/230 (180 degrees only)
3780W/5400VA at 110/220 (180 degrees only)
3360W/4800VA at 100/200 (180 degrees only)
Dimensions (W x D x H) 6.9 in. x 24.2 in. x 16.9 in. (176 x 615 x 430)
Racking Units 4U
Weight 161 lbs.
Nominal Operating Frequency 50 or 60 Hz (Factory Default = 60)
Factory Default VAC 120/208 VAC at 120 degrees
L1-L2 Factory Default Input Phase Angle  120 degrees
Allowable Input Phase Angle 120, 180, 240 degrees, Auto-sensing on application of AC (Restrictions for L-N voltages other than 120 VAC)
User Configurable L1-N, L2-N VAC 100/110/115/120/127 VAC (May be modified using configuration program)
L1-N, L2-N, Operating Voltage Range Without Battery Operation (Except 100 VAC L-N Operation) 100% - 90% loading: 90 VAC - 140 VAC
90% - 70% loading: 80 VAC - 140 VAC
70% - 30% loading: 70 VAC - 140 VAC
30% - 0% loading: 60 VAC - 140 VAC
L1-N, L2-N, Operating Voltage Range Without Battery Operation (100 VAC L-N Operation) 100% - 70% loading: 80 VAC - 140 VAC
70% - 30% loading: 70 VAC - 140 VAC
30% - 0% loading: 60 VAC - 140 VAC
L1-N, L2-N Max. Allowable VAC 150 VAC
Input Frequency w/o Battery Operation 40 - 70 Hz
Input Power Connection See Distribution Box Options
Factory Default Output VAC 120/208 VAC @ 120 degrees
L1-L2 Factory Default Output Phase Angle 120 degrees
Allowable Output Phase Angle 120, 180, 240 degrees Auto-sensing on initial application of input AC
Factory Default L1-N, L2-N VAC 120 VAC nominal
User Configurable L1-N, L2-N VAC 100/110/115/120/127 VAC, ±3%
Output Connections See Distribution Box Options
Frequency 50 Hz or 60 Hz, Nominal
Waveform Sinewave
Main Mode Overload 200% for 8 cycles; 130% for 10 seconds with transfer to bypass
Disable Bypass operation If input voltage exceeds ±15% of the nominal voltage
Re-enable Bypass operation If input voltage returns to within ±10% of nominal output voltage
Disable Bypass operation When the input frequency prevents synchronous operation
Operating Temp +32°F to +104°F (0°C to +40°C)
Storage Temp +5°F to +122°F (-15°C to +50°C)
Relative Humidity 0% to 95%, non-condensing
Operating Elevation Up to 10,000 ft. (3000m) at 104°F (40°C) without derating
Storage Elevation 50,000 ft. (15,000 m) maximum
Audible Noise <55 dBA, at 1 meter from the rear
<50 dBA, at 1 meter from the front or sides
Safety UL 1778, c-UL Listed (Suitable for computer room applications)
RFI/EMI FCC Part 15, Subpart B, Class A
Surge Immunity IEEE/ANSI C62.41 Category A & B
Transportation ISTA Procedure 1A
PD-HDWR Distribution Box Amp Rating 24 Amps
PD-HDWR Distribution Box Input Power Connection 4-Wire Hardwired, 8-10AWG
PD-HDWR Distribution Box Output Power Connection 4-Wire Hardwired, 8-10AWG
PD-HDWR Distribution Box Input Branch Circuit Breaker 30 Amp, Supplied by User

Technical Notes

An On-Line UPS has longer battery life than Stand-By technology. Size the UPS to the load and then add extra battery modules if extended run time is desired. The unit may also be mounted vertically as a free standing tower. Requires 30 Amp service.

Unit comes with rack ears (securing flanges) but these do not support the weight of the unit. An optional rail kit (see below) is required.

Server or mission critical device protection. Online provides a pure signal and completely isolates equipment from the power grid.